Here are a couple things to check. Your water well pump is not working.
How To Check Your Well Tank S Pressure Fresh Water Systems
Well pressure switch not turning on. If it has tripped you will. When you have a power failure and continue to use water the pressure switch which has a gray plastic cover and is located near your wells pressure tank will have to be reset. Check the well tank pressure gauge to see if it is at least 40. Water is life started by imacdad feb 16 2012. Debris can get lodged inside the bottom of your pressure switch and blind it from reading the pressure which can cause the pump to run intermittently and sometimes not at all. If banging on the tube under the pressure switch kicked on the well pump it means the contact surfaces of the electrical contacts are pitted or burned causing a poor connection.
Debris can get lodged inside the bottom of your pressure switch and blind it from reading the pressure which can cause the pump to run intermittently and sometime not at all. Before you unscrew this pipe youll need to verify power is off and drain all the pressure from your system. Slap your adjustable wrench around the flats on the gauge and unscrew it. What happens is that when the pressure tank pressure falls below the low setting usually between 20 and 35 psi it causes the pressure switch to turn off. Check that the pressure control switch is not stuck debris or silt clogging can prevent a water pump pressure switch from properly responding to changes in water pressure. Double check that power is running to your well and that there isnt a short.
Works fine for a few days. You can temporarily restore the surfaces to keep it going until you can buy a replacement switch. Check the water pump breaker in your electrical box to make sure the breaker hasnt tripped. First turn off the power and double check with a voltage tester. The new switch works intermittantly. This past weekend i replaced the pressure switch because the old one was sticking open.
Pressure switch not turning off. New pressure switch not turning on pump. Label each wire with tape. If the pump is not creating enough pressure to signal the switch to turn off it is possible the pump could need to be replaced. I have a submersible pump on 220v with a large diaphragm tank on a 3050 system. Verify that your pump is creating enough pressure to signal the pressure switch to turn off.
Feb 16 2012 location. Then screw in a new one and tighten it down. This is how you check your standard well pump to see if you can get the water back on again. Your well pump gets its marching orders from the switch mounted on. Then unscrew the conduit locking ring and pull the wires and conduit out of the switch. Upstate south carolina.
I put in the large tank to reduce pump usage. Discussion in pumps and tanks well forum blog.