If you want to have control from more than three locationsfor example five locationsyou would. I usually use a factor of 2 to allow for later additions.
Eaton Vgfs15wmsp 15amp 125volt Combination Ground Fault
Light switch amp rating. The maximum amp rating at 125 volts ac for the same switch is 15 amps. Light switchestend to be rated for 15 amps 20 is less common and may control up to their amp rating worth of lights. 06 june 2007 at 0640 am by jaymack top. Wiring a new light switch from receptacle. Double pole switches are commonly rated for 30 amps compared to 15 or 20 amps with standard switches. Depending on con tact spreading velocity and thermal mass of the cont acts this.
This allows the switches to control power feeding higher demand appliances motors and machinery. This official sponsor may provide discounts for members. These onoff heavy duty push switches range between 3 amp 250 volt and 6 amp 125 volt capacities. The four way switch is used between two three way switches to provide control for an outlet or light fixture from three or more different locations. Toggle switch ratings table from microswitch catalog elect code rating 28 vdc 115 vdc 250 vdc 115 vac 230 vac ind res lamp res res ind res lamp res 1 15 20 5 75 5 10 15 3 6 2 10 15 4 75 5 7 15 2 6 3 15 20 7 75 5 15 15 4 6 4 10 18 5 75 5 8 11 2 6 5 12 20 5 75 5 15 15 4 6 6 10 18 4 75 5 8 11 2 6 most damage to switches is done during the breaking of a circ uit where an arc forms in the widening gap. The osg page 85 note 2 says that the demand va for final circuits to discharge lighting is taken as the lamp watts multiplied by not less than 18.
For example a switch rated for 15 a at 250 vac will only be rated for 15 a. The switch is an electronic switch rated at 3 amps. Therefore in all cases the accessory must be wired through a fused relay. This switch allows you to operate any 12 volt accessories. American professional electrical advice forum. A switch rated for 20 amps at 125v ac or 10 amps at 250v ac would typically have a current rating of less than 1 amp at 125v dc and yet the only difference was going from 125 volts ac to 125 volts dc.
For a 6 amp rated switch say switchable duty would be 3as worth of fluorescents. Reply to light switch ratings amp volts. 06 june 2007 0818 am. A push switch describes any type of mechanism that activates skip to main content. It is usual to derate the amp rating for standard light switches where there are fluorescents. Thread starter similar threads forum replies date.
Facebook twitter reddit pinterest tumblr whatsapp email link. So a switch on a circuit with a 20 amp breaker could be rated 15 amps as long as it was not controlling over 15 amps of lights. For the same current rating the dc voltage rating on a switch will generally be much lower than its ac voltage rating. So in the example below the maximum amp rating for this switch at 250 volts ac vac is 10 amps. The amp rating of a carling switch is the maximum current in amperes the switch will carry continuously. Tamper resistant light switch 15 amp need key.