Connect the black fan cable together with the black light wire and the black switch wire and cover them. Run 3 conductor wire with a ground to the new fanlight.
Maxxair 0007000k Maxxfan Deluxe Fan With Remote And White Lid
How to wire a 3 function bath fan. Red black white and ground. Using wire strippers peel an inch of insulation from the end of the black and white wires. Inside the box youll need to separate the wires to see which feed the fan and which feed the light. If you have one of these you may have wired the fan and light to separate switches. That was using 3 14 2 going to the new fan light. 2 i dont want a 3 function switch i want one switch controlling the fan and light function simultaneously.
The 3 load hot wires on the. Combination light fan and heating units can be incredibly helpful in smaller bathrooms and similar areas in your home not served by heating vents. That detail greatly simplifies the electrical procedure youre about to undertake. 3 i need to have another light in the bathroom controlled by the same switch that controls the 2 fan functions. You have essentially created two separate circuits within the connection box. Connect the white wires the ground wires the black wires and the red wires together.
If the light and fan are separate fixtures youre going to have to run a short length of wire through the attic. Now youd like to operate both of them from the same switch. The incoming or line hot wire on the common screw on the switch. I tried a few. The instruction manual gives no instructions for how to wire this other than using the 3 function switch. Bathroom exhaust fans with built in light fixtures are fairly common.
The wires are already where you need them to be so you dont have to run new ones. The compact form and varied functions make them perfect for use with a three function switch box but youll need to be careful installing the system. Connect the white wires in the same way then repeat with the ground wires. Also keep in mind that the junction box in the bath fan combo unit is typically small with just enough space for making up the lead wire connections with the wires from the switches so if the power was been extended up into the ceiling then you will most likely have to install an accessible junction box just for the power source then from there a 3 wire cable to the wall switch and another 3 wire cable to the combo unit. All white wires will get wired together. On the other side of the switch you will have 3 terminals.
You will wire one of the black wires to one of those terminals the second black wire to the second terminal and the 3 black wire to the 3rd terminal.